Schneider Electric Conext MPPT 60 150 Solar Charge Controller
The Schneider Electric Conext MPPT Solar Charge Controller is a photovoltaic (PV) charge controller that tracks the electrical maximum power point of a PV array to deliver the maximum available current for charging batteries. When charging, it regulates battery voltage and output current based on the amount of energy available from the PV array and state-of-charge of the battery.
The Conext MPPT can be used with 12, 24, 36, 48, and 60-volt DC battery systems and is able to charge a lower nominal-voltage battery from a higher nominal-voltage array. For example, the XW SCC can charge a 12-volt battery from a 36-volt array. This provides flexibility for installers to use longer wiring runs without compromising efficiency. The Conext Solar Charge Controller can be installed (in single or multi-unit configurations) with Schneider Electric Hybrid Inverter/Charger(s) or can be used in other solar energy systems where a solar charge controller is needed.
The Schneider Electric Conext MPPT incorporates a dynamic Maximum Power Point Tracking (MPPT) algorithm designed to maximize energy harvest from the PV array. The MPPT constantly adjusts the operating points of the array to ensure it stays on the maximum power point. It does not stop energy harvest to sweep the array like some other competing products. This feature is beneficial all sunlight conditions, especially
in areas with fast moving cloud cover and quickly changing solar conditions.
Standard features of the Solar Charge Controller include:
- Maximum Power Point Tracking (MPPT) delivers maximum available power from PV array to battery bank
- Integrated PV ground-fault protection
- Ultra-reliable, convection-cooled design does not require a cooling fan – large, aluminum, die-cast heat-sink allows full output current up to 45°C without thermal derating
- Selectable two or three-stage charging algorithms with manual equalization to maximize system performance and improve battery life
- Configurable auxiliary output
- Two-line, 16-character liquid crystal display (LCD) and four buttons for configuration and system monitoring
- Input over-voltage and under-voltage protection, output over-current protection, and back feed (reverse current) protection (warning and fault messages appear on LCD when unit shuts down as a protective measure)
- Over-temperature protection and power derating when output power and ambient temperature are high
- Battery Temperature Sensor (BTS) included – automatically provides temperature compensated battery charging
- Xanbus™-enabled network communications protocol (developed by Xantrex)
- Communicates settings and activity to other Xanbus™-enabled devices, such as the Schneider Electric Conext Hybrid Inverter/Charger, the Schneider Electric Conext System Control Panel (SCP), Schneider Electric Conext Automatic Generator Start (AGS), and other Schneider Electric Conext Solar Charge Controllers.
- Five-year warranty
Nominal battery voltage: 12, 24, 36, 48, 60 Vdc
Maximum PV array voltage (operating): 140 Vdc
Maximum PV array open circuit voltage: 150 Vdc
Array short-circuit current: 60 Adc maximum
Maximum and minimum wire size in conduit: #6 AWG to #14 AWG
Total power consumption while operating: 2.5 W (tare)
Charger regulation method:
- Three-stage (bulk, absorption, float)
- Two-stage (bulk, absorption)
Mechanical Specifications
Dimensions (HWD): 14 ½ × 5 ¾ × 5 ½” / 368 × 146 × 138 mm
Weight (Controller only): 10.75 lb (4.8 kg)
Reviews
There are no reviews yet.